The National Examinations Council (NECO) has officially commenced applications for registration of qualified Computer-Based Examination (CBE) Centre Operators. This initiative comes as NECO fully transitions from Pen and Paper Test (PPT) to Computer-Based Examination (CBE) beginning with the 2025 November/December Senior School Certificate Examination (SSCE) External.

Interested CBT centre operators are required to meet specific requirements to ensure the smooth conduct of NECO examinations across the country.

System Requirements

  1. 1. Minimum of 150 functional computer systems/laptops with 10% (15 systems) as backup.
    • Intel-based processor: Dual Core Celeron/Pentium
    • RAM: 4GB minimum
    • Storage: SSD preferred, 32GB minimum
    • Windows 10 OS
    • 10 / 100MB RJ45 Network Port
    • Latest version of Chrome, Firefox, or Edge browser
  2. Computer monitor: Minimum 15 inches (desktop) or 14 inches (laptop).
  3. Computers must connect to a robust server with capacity for 150 systems concurrently.
  4. Systems must be virus-free with updated antivirus.
  5. LAN (wired star topology) required; wireless connections are not allowed.
  6. Switches must have uninterrupted power supply throughout exams.
  7. Each centre must have Gigabit switches with two backups.
JAMB CBT centre , NECO CBT prototype

NECO Hall Requirements

  1. Individual cubicles for candidates (26” length × 18” breadth × 18” height) with proper seating.
  2. Adequate air-conditioning and lighting.
  3. Functional CCTV network with IP cameras for monitoring.
  4. CCTV must be cabled (no wireless allowed).
  5. No exposed cables; all must be trunked neatly.
  6. Strong MTN or Airtel network signal at centre location.
  7. Wall clocks visible to all candidates (wristwatches banned in halls).
  8. Centres must be dedicated CBT centres, not makeshift facilities.
  9. Shared premises (e.g., cinema halls, shopping malls, markets) are not allowed.

Facilities and Personnel Requirements

  1. Backup power: 40KVA generator minimum for centres with 250 systems, plus UPS / inverters for at least 3 hours runtime.
  2. Minimum of two technical personnel and one network engineer.
  3. Staff must be dependable, trustworthy, and of high integrity to maintain exam credibility.
  4. Provision of holding/reception area (e.g., canopy with chairs).
  5. Internal toilets must be available inside the CBT hall.
  6. Adequate security personnel for facilities.
  7. Centres must be fenced and secured.

Application and Accreditation

Interested operators should download full guidelines from the NECO portal: https://cbt.neco.gov.ng.
Complete the online application form and submit with required documents.
Successful applicants will undergo inspection and accreditation.
Accredited centres must strictly comply with NECO regulations.